Apollo LM insulation susceptible to degradation from cabin leakage during pressurized conditions

Maxime A. Faget, MSC Director of Engineering and Development, told the ASPO Manager that he had reviewed the LM insulation status and concluded that "the present design is susceptible to degradation from cabin leakage during pressurized conditions.

The present insulation design is unacceptable for the lunar landing mission." He agreed with the contractor that design changes were required and specified that the insulation design change should be effective on LM-4 and the changes should be installed for the LTA-8 tests in support of LM-5.