Home - Search - Browse - Alphabetic Index: 0- 1- 2- 3- 4- 5- 6- 7- 8- 9 A- B- C- D- E- F- G- H- I- J- K- L- M- N- O- P- Q- R- S- T- U- V- W- X- Y- Z More Details for 1965-12-10
At-sea operational qualification tests, using boilerplate 29 to simulate spacecraft 009, were completed. All mechanical system components performed satisfactorily, except for the recovery flashing light.
Test results were: - uprighting system - during the first mission cycle, the vehicle was uprighted in three minutes, during the second, in two minutes; - VHF antenna deployment - the antennas were in the erect position when the test started. Communication was achieved with a fly-by plane; - the sea dye marker canister deployed as expected when the HF was erected; and - the recovery flashing light was deployed before the test started; when switched on the light did not flash. Post-test analysis indicated a water-short in the wiring installed by MSC.